Explosives load based on 1.0 g/cc. To achieve explosives load for other product densities, multiply load per metre by that product density. Metric Column Load Formula kg / m = (0.785 X De2 X d) / 1000
Where: d = Density of Explosives in g/cc De = Hole Diameter in mm |
Example 0.84 g/cc in 127mm hole Explosive Load: 12.66 X 0.84 = 10.63 kg/m Explosives Column Diameter, mm | Explosives Load kg/m | Explosives Column Diameter, mm | Explosives Load, kg/m | | 19 | 0.28 | 178 | 24.82 | | 22 | 0.39 | 184 | 26.6 | | 25 | 0.51 | 191 | 28.5 | | 29 | 0.64 | 200 | 31.4 | | 32 | 0.79 | 203 | 32.4 | | 35 | 0.96 | 210 | 34.5 | | 38 | 1.14 | 216 | 36.6 | | 41 | 1.34 | 222 | 38.8 | | 44 | 1.55 | 229 | 41.0 | | 48 | 1.78 | 235 | 43.3 | | 51 | 2.03 | 241 | 45.7 | | 57 | 2.56 | 251 | 49.4 | | 64 | 3.17 | 254 | 50.6 | | 70 | 3.83 | 260 | 53.2 | | 76 | 4.56 | 267 | 55.8 | | 83 | 5.35 | 270 | 57.2 | | 89 | 6.20 | 279 | 61.3 | | 95 | 7.12 | 286 | 64.1 | | 102 | 8.10 | 292 | 67.0 | | 108 | 9.15 | 298 | 69.9 | | 114 | 10.26 | 305 | 72.9 | | 121 | 11.43 | 311 | 76.0 | | 127 | 12.66 | 318 | 79.1 | | 133 | 13.96 | 324 | 82.3 | | 140 | 15.32 | 330 | 85.6 | | 146 | 16.74 | 349 | 95.8 | | 152 | 18.23 | 356 | 99.3 | | 159 | 19.78 | 368 | 106.5 | | 165 | 21.40 | 381 | 114.0 | | 171 | 23.08 | 394 | 121.7 |
|